Description
5740 691 Norton Door Controls Door Closer
The 5700 patented design is based on ease and simplicity. This operator installs in minutes rather than hours and consists of three basic components: inverter, motor and NortonÃs 1601 closer body. What separates the 5700 from other operators is its ability to function as a standard door closer. When the door is opened manually, there is little resistance and the drive train and motor are not engaged. The 1601 closer, not the motor, controls the closing cycle. Since the door closer does not back-drive the motor during the closing cycle, there is no loss of closer efficiency. In the event of a power outage, the door can be manually opened and will close via the door closerÃs spring force. The 5700 is ideal for doctor's offices, retirement facilities, schools or churches. Based on its dual functionality, ease of use and quiet operation, the 5700 offers the customer a unique choice.
- Door Controls (interior) (exterior) swinging door(s) shall be of rack and pinion design contained within a precision cast aluminum housing.
- Door closing force shall be adjustable to ensure adequate closing control.
- Door closing speed shall be controlled by independent hydraulic adjustment valves in the sweep and latch range of the closing cycle.
- Door Operator shall provide conventional door closer opening forces unless the power operator motor is activated.
- Door Operator shall provide conventional door closing forces at all times except in the event of power outage during powered door open cycle.
- Door Operator opening force and speed shall be adjustable by independent electronic adjustment to ensure adequate opening control per accessibility codes.
- Door Operator shall have an adjustable hydraulic backcheck valve to cushion the door speed if door is opened violently.
- Door Operator shall have a manual adjustment to locate both full open and full closed door positions.
- Maximum door open shall be adjustable and capable to a maximum 180° conditions permitting. [(Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e., wall switch, etc.)]
- Door operator shall have adjustable hold open time capability in range from 5 to 30 seconds.
- Door operator shall have input line rating of 120VAC, .6A or 240VAC, .3A.
- Units shall have relay contact for interfacing products having a contact rating of 30VDC at 1A or 125VAC at .5A.
- Unit shall have an external On/Off Switch to defeat powered opening when desired.
- Unit shall have an internal circuit breaker switch to interrupt input power for servicing.
- Unit shall be U.L. Listed for automatic closing door.
- Unit shall be in compliance with the requirements of the Americans With Disabilities Act (ADA), ANSI standards A117.1 and A156.19.
- Unit shall meet C-UL US.